CK40N: Unexplained message CO 522 in log
[424] [Background] [CK] [co.in] [job] [log in] [tagged log in] [yahoo.co.in]
Symptom
You execute the costing step in a costing run. Even though you cost assemblies with BOMs and routings, all components from the BOM are missing in the costing result. In the log, the system issues warning message CO 522 (Material & not found) without an additional explanation.
Other terms
Background, job, CK 424
Reason and Prerequisites
When you execute the costing run, you do not have the authorization to explode BOMs. The “selection” and “structure explosion” steps in the costing run were executed in dialog processing.
Solution
Implement the attached corrections. As a result, the system issues warning message CK 581 if an authorization is missing.
If you want the system to execute this message as an error message, this must first be connected to flexible error management. To do so, use transaction SM30 to create a new entry in the view V_TCMF9:
ErrorMgtID Application Area MsgNo:
—————————–
CK CK 581